When it comes to electrical installations, safety should always be a top priority. One crucial component of any installation is the termination kit, which is vital in joining electrical conductors to other equipment or components. However, it's not as simple as just connecting two wires together. To ensure proper safety and performance, earth braid is used as a protective measure. In this article, we will discuss the installation requirements for earth braid with the heat shrinkable termination kit.
General Information about Earth Braid
Earth braid is a highly conductive, flexible, and durable flat strap made of tinned copper or copper alloy. It is used for shielding, grounding, or protecting electrical components from electromagnetic interference (EMI). Earth braid can also protect against voltage spikes and other electrical surges, which could cause severe damage to devices or equipment. They come in different sizes, but the most common sizes for electrical applications are 16mm², 25mm², and 35mm².
Heat Shrinkable Termination Kit
A heat shrinkable termination kit is a product that connects metallic or non-metallic lugs to the cable end and provides environmental protection to the joint. It is composed of different parts, including the tubing, adhesive, stress control tube, and connector. Heat shrinkable tubing is wrapped around the cable joint and shrinks when heated, conforming to the shape of the joint and creating a seal.
Earth Braid Installation Requirements for Heat Shrinkable Termination Kit
The installation of earth braid for the heat shrinkable termination kit requires specific guidelines to ensure that it performs its intended function correctly. Here are the installation steps for earth braid:
Step 1: Cut the earth braid to the required length and remove the insulation. Make sure the earth braid fits securely around the cable insulation.
Step 2: Install the connector to the earth braid, ensuring it's a tight fit.
Step 3: Install the connector to the metallic lug (or cable end).
Step 4: Slide the stress control tube over the metallic lug.
Step 5: Insert the metallic lug and the earth braid into the heat shrinkable tubing and ensure there is no gap between them.
Step 6: Shrink the tubing with a heat gun or other suitable heat source.
Step 7: Take a multimeter reading to verify the connection resistance is within the allowable limit.
Conclusion
In conclusion, the installation requirements for earth braid with the heat shrinkable termination kit are essential to ensure that the electrical installation is safe and performing as intended. Follow the installation steps mentioned above while adhering to the specific guidelines, and you will have a solid grounding connection for your electrical installation.